Eaton Legacy BR240 Molded Case Circuit Breaker, 120/240 VAC, 40 A, 10 kA Interrupt, 2 -Pole

Eaton Legacy BR240 Molded Case Circuit Breaker, 120/240 VAC, 40 A, 10 kA Interrupt, 2 -Pole

  • Manufacturer: Eaton
  • Brand Name: Eaton Legacy
  • Part#: BFMBR240
  • MPN: BR240
  • UPC: 786676363006
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Availability: loading
  • Branch Availability

EATON Type BR plug-in breakers in the standard 1 in per pole molded case and can be used as main and/or branch disconnect devices. All are CSA and UL listed. Typical ampacity range for BR breakers is 15 through 125 A.

Eaton Legacy Molded Case Circuit Breaker, 40 A, 120/240 VAC, 10 kA Interrupt Rating, 2 Poles, 1 ph Phase, Common, Thermal Magnetic Trip, NEMA 1, 3R, 4X Enclosure, 14 to 4 AWG Wire, Plug-On Mounting, 600 to 750 deg C, 2 in Width, 3 in Length, 3 in Height

Amperage Rating      :      40 A
Enclosure Type      :      NEMA 1, 3R, 4X
Height      :      3 in
Interrupt Rating      :      10 kA
Length      :      3 in
Mounting Type      :      Plug-On
Number of Poles      :      2
Phase      :      1 ph
Temperature Rating      :      600 to 750 deg C
Trip Type      :      Common, Thermal Magnetic
Voltage Rating      :      120/240 VAC
Width      :      2 in
Wire Size      :      14 to 4 AWG
  • All BR circuit breakers have rejection tab feature
  • Units feature a quick make, quick break switch mechanism combined with inverse time element tripping operation and trip-free handle design
  • Standard interrupting capacity
  • All are type IC (interchangeable) devices, several ratings are SWD and HARC approved
  • Contacts shall be of non welding silver alloy
  • All circuit breakers shall have the trip rating inscribed on the handle on each circuit breaker pole
  • Circuit breakers shall be completely enclosed in a molded case of thermoset material
  • Terminals shall be of the box lug or clamp type design
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Cutler_Hammer_BR250_Catalog.pdf
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/EATON_BR120_Catalog.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/EATON_BR240_Specification_Sheet.pdf