Website will be down for maintenance between 9pm Sunday evening to 4am Monday morning.

You will not be able to see pricing, product availability, place online orders, check account AR and order history, or register new users during this time.

All items that have been added to your shopping cart prior to the maintenance window, will still be present in your shopping cart once the maintenance is completed.

  1. pin-int

Weil-McLain® Evergreen Pro 1 EVG-110 Gas Boiler, 95 % AFUE, 110 MBtu/hr, 2.5 gal Capacity, 0 to 10 V

Weil-McLain® Evergreen Pro 1 EVG-110 Gas Boiler, 95 % AFUE, 110 MBtu/hr, 2.5 gal Capacity, 0 to 10 V

  • Manufacturer: Weil-McLain
  • Brand Name: Weil-McLain®
  • Part#: WMCEVG-110
  • MPN: EVG-110
  • UPC: 672619209527
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Availability: loading
  • Branch Availability

Weil-McLain® Evergreen Pro Gas Boiler, Series: 1, 0 to 10 V, 95 % AFUE, 110 MBtu/hr, 2.5 gal Capacity, 30 psi, Natural Gas, Propane Gas Fuel, Direct Vent, 3 in Chimney/Breeching/Vent, 101 mbh DOE Heating Capacity, 88 MBtu/hr Net BTU Rating, Floor Standing, Wall Mounting, Stainless Steel, 17-5/8 in W x 18-5/8 in D

AFUE Rating      :      95 %
BTU Rating      :      110 MBtu/hr
Capacity      :      2.5 gal
Chimney/Breeching/Vent Size      :      3 in
DOE Heating Capacity      :      101 mbh
Dimensions      :      17-5/8 in W x 18-5/8 in D
Fuel Type      :      Natural Gas, Propane Gas
Material      :      Stainless Steel
Mounting Type      :      Floor Standing, Wall
Net BTU Rating      :      88 MBtu/hr
Pressure Rating      :      30 psi
Series      :      1
Vent Type      :      Direct
Voltage Rating      :      0 to 10 V
  • Stainless steel fire tube heat exchanger with non-metallic base
  • Floor standing or wall mount boiler (optional wall mount kit for 220 to 399 sizes)
  • Modulating condensing boiler
  • 95% AFUE (110-299), 96.5% combustion efficiency
  • Four pump/auxiliary outputs
  • Up to 8 multiple boiler control with lead/lag rotation
  • Modbus® to BMS connectivity
  • Each input can be assigned to a priority (up to three priorities)
  • Multiple Inputs can be assigned one priority (zone based control)
  • All lag boiler inputs and output can be used
  • Configurable auxiliary input/output system
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Weil_McLain_EVG_110_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Weil_McLain_EVG_110_Instruction_Installation_Manual.pdf
  • pdfLine Drawing https://assets.unilogcorp.com/267/ITEM/DOC/Weil_McLain_EVG_110_Line_Drawing.pdf
  • pdfOwners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Weil_McLain_EVG_110_Owners_User_Manual.pdf
  • pdfWarranty Information https://assets.unilogcorp.com/267/ITEM/DOC/Weil_McLain_EVG_110_Warranty.pdf