  1. pin-int

Rehau® PRO-BALANCE® 281541-001 Pressure Differential Bypass Module, 1 in Nominal, BSPP

Rehau® PRO-BALANCE® 281541-001 Pressure Differential Bypass Module, 1 in Nominal, BSPP

  • Manufacturer: Rehau
  • Brand Name: Rehau®
  • Part#: REH281541-001
  • MPN: 281541-001
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Availability: loading
  • Branch Availability

Rehau® PRO-BALANCE® pressure differential bypass valve module is recommended for use in heating systems using manifolds with valve actuators or when the flow output of one circulator pump is controlled by multiple zone valves. The bypass valve diverts excess flow when one or more actuators (of zone valves) closes, preventing excessive flow velocities. The benefits of this are reduced wear on the pump, reduction or elimination of noise problems in valves and pipes and more stable temperature control. The Rehau® PRO-BALANCE® pressure differential bypass valve module is simply-mounted onto the PRO-BALANCE® manifold. Ensure that the arrow on the valve body is pointing from the high-pressure side to the low pressure side of the manifold. Flat gaskets are supplied and the union nuts should be securely tightened.

Rehau® PRO-BALANCE® Pressure Differential Bypass Module, 1 in Nominal, BSPP Connection, 8.26 in L x 2.16 in W

Connection Type      :      BSPP
Dimensions      :      8.26 in L x 2.16 in W
Nominal Size      :      1 in
  • Modular accessory connects directly to 1 in PRO-BALANCE® or HLV brass manifolds
  • Normally, a constant speed circulator is sized assuming that all circuits in a zone valve system may be open
  • The pressure differential bypass module provides a means to control the excess flow (velocity) that would otherwise occur when actuators close
  • Installation of this module onto the 1 in probalance or HLV manifolds creates an automatically regulated flow path such that operating zone circuits do not see unnecessarily high-flow
  • For 1 in brass manifolds
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Rehau_281541_001_Catalog.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Rehau_281541_001_Specification_Sheet.pdf