The YELLOW JACKET® Combustion Analyzer (CA502) is an essential tool for ensuring the safety, efficiency, and proper operation of heating appliances. With six simultaneous readings displayed, CA502 is among the best in the industry. Compact and lightweight, the analyzer with a magnetic protective holster fits in the palm of your hand. The CO over-limit protection provides sensor longevity and the 7" duct probe with adjustable depth stop allows for easy installation and use at any jobsite. A wireless printer option and YJ Combustion App make the YELLOW JACKET® Combustion Analyzer the simplest combustion analyzer on the market. The inline condensate trap and soot filter provides easy viewing and easy change out and cleanup at the end of a job. A replaceable filter is integrated into the suction line and can be easily replaced while emptying the water trap. The onboard pre-calibrated O2 sensors are easily field-replaceable, allowing for reduced downtime.
Yellow Jacket® Combustion Analyzer, Backlit Display, 0 to 25% Volume O2, 0 to 4000 ppm CO High Immunity, 0 to 99.9% Volume CO2, -4 to 248 deg F Air Temperature, -4 to 1472 deg F Flue Gas Temperature, 31 to 1472 deg F Temperature Differential, 0 to 9.5 Air Index, 0 to 850 % Excess Air, 0 to 100% Stack Losses, 0 to 120% Efficiency Measuring, +/-0.2% O2, 0 to 400 ppm CO High Immunity, +/-33.8 deg F Air Temperature, 32 to 212 deg F Flue Gas Temperature, -40.1 to -0.81 inH20 Accuracy, 0.1% Volume O2, 1 ppm CO High Immunity, 0.1% Volume CO2, 32.18 deg F Air Temperature, -20 to 800 deg C Flue Gas Temperature, -40.1 to 80.4 inH20 Pressure, 0.1 deg C Temperature Differential, 0.1 Air Index, 1% Excess Air, 0.1% Stack Losses, 0.1% Efficiency Resolution
Accuracy | : | +/-0.2% O2, 0 to 400 ppm CO High Immunity, +/-33.8 deg F Air Temperature, 32 to 212 deg F Flue Gas Temperature, -40.1 to -0.81 inH20 |
Display Type | : | Backlit |
Measuring Range | : | 0 to 25% Volume O2, 0 to 4000 ppm CO High Immunity, 0 to 99.9% Volume CO2, -4 to 248 deg F Air Temperature, -4 to 1472 deg F Flue Gas Temperature, 31 to 1472 deg F Temperature Differential, 0 to 9.5 Air Index, 0 to 850 % Excess Air, 0 to 100% Stack Losses, 0 to 120% Efficiency |
Resolution | : | 0.1% Volume O2, 1 ppm CO High Immunity, 0.1% Volume CO2, 32.18 deg F Air Temperature, -20 to 800 deg C Flue Gas Temperature, -40.1 to 80.4 inH20 Pressure, 0.1 deg C Temperature Differential, 0.1 Air Index, 1% Excess Air, 0.1% Stack Losses, 0.1% Efficiency |