The FTVN is a high-efficiency, wall-hung boiler using a durable, vertical down-fired stainless heat exchanger. With 10:1 modulation and 96% AFU, an integrated ECM pump and DHW diverter, quick connect components, Wi-Fi connectivity for remote monitoring and alert notifications, the FTVN is an ideal solution for your peace of mind, home heating needs.
NTI High-Efficiency Gas-Fired Tube Condensing Boiler, 120 VAC, 12 A, 60 Hz Frequency, 1 ph, 95 % AFUE, 110000 Btu/hr BTU, 50 psi Pressure, 3/4 in MNPT Gas, 1-1/4 in MNPT Water Connection, Liquid Propane Gas, Natural Gas Fuel, Exhaust Vent, Chimney/Breeching/Vent Size: 2 in, 101 mbh DOE Heating, 2 in Flue Outlet, Direct Spark Ignition, 88 mbh Net IBR, Wall Mounting, Stainless Steel, Dimensions: 37-1/4 in H x 19-1/2 in W x 18-1/2 in D
| AFUE Rating |
: |
95 % |
| Amperage Rating |
: |
12 A |
| BTU Rating |
: |
110000 Btu/hr |
| Chimney/Breeching/Vent Size |
: |
2 in |
| Connection Type |
: |
3/4 in MNPT Gas, 1-1/4 in MNPT Water |
| DOE Heating Capacity |
: |
101 mbh |
| Dimensions |
: |
37-1/4 in H x 19-1/2 in W x 18-1/2 in D |
| Flue Outlet Size |
: |
2 in |
| Frequency Rating |
: |
60 Hz |
| Fuel Type |
: |
Liquid Propane Gas, Natural Gas |
| Ignition Type |
: |
Direct Spark |
| Material |
: |
Stainless Steel |
| Mounting Type |
: |
Wall |
| Net IBR Rating |
: |
88 mbh |
| Phase |
: |
1 ph |
| Pressure Rating |
: |
50 psi |
| Vent Type |
: |
Exhaust |
| Voltage Rating |
: |
120 VAC |
- Fire tube chromium stainless steel heat exchanger
- Vertical down fired stainless steel heat exchanger for exceptional efficiency and durability
- Wi-Fi on board for remote control and monitoring
- Integrated ECM pump and DHW diverter valve on all models
- ASME H stamped boiler, designed and constructed in compliance with the ASME boiler and pressure vessel code section IV
- Modulating burner with 10:1 turndown ratio
- (2) 120 VAC outputs for external circulators
- Zero clearance to combustibles (clearances required for service)
- Small zone valve systems may not require an additional pump or a low loss header
- CH zone input x 2 (on/off switch or NTI room sensor)
- Outdoor temperature sensor input (or access weather via Wi-Fi connection)
- Easy service access and quick component connections
- Internal diverter valve eliminates need for indirect pump
- Certified as direct vent (sealed combustion) or for use with indoor combustion air
- Sealed cabinet and integrated condensate trap
- High energy ignition transformer (spark ignition)
- Built-in water pressure bypass (guarantees minimum water flow)
- Low water pressure switch
- Integrated ECM boiler circulator
- Integrated 3-way valve (diverts between DHW and CH demands)
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/NTI_FTVN110_Catalog.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/NTI_FTVN110_Specification_Sheet.pdf
-
Warranty Information
https://assets.unilogcorp.com/267/ITEM/DOC/NTI_FTVN110_Warranty.pdf
-
Video Link
https://youtu.be/MzcRhkO0QPU
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/NTI_FTVN110_Catalog.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/NTI_FTVN110_Specification_Sheet.pdf
-
Video Link
https://youtu.be/MzcRhkO0QPU
-
Warranty Information
https://assets.unilogcorp.com/267/ITEM/DOC/NTI_FTVN110_Warranty.pdf