Bard® Heat Pump Package Unit, Series: WH, WH242-C Model, 2 ton Nominal, 23600 Btu/hr Cooling Cooling BTU Rating, 23200 Btu/hr Heating Heating BTU Rating, 460 VAC, 17 A, 1/5 hp Fan Motor, 1/6 hp Blower Motor, 60 Hz, 3 -Phase, 1075 rev/min Fan Motor, 1100 rev/min Blower Motor, Scroll Compressor, 1600 cu-ft/min Fan Motor, 800 cu-ft/min Blower Motor, 10.5 SEER, HSPF: 6.6, R-22 Refrigerant, 20 A Fuse, Wall Mounting, 16 x 25 x 1 in Filter, 20 ga Steel, Galvanized, Zinc-Coated, Buckeye Gray, 33.3 in W x 70.5625 in H x 17.125 in D
Amperage Rating |
: |
17 A |
CFM Rating |
: |
1600 cu-ft/min Fan Motor, 800 cu-ft/min Blower Motor |
Color |
: |
Buckeye Gray |
Compressor Type |
: |
Scroll |
Cooling BTU Rating |
: |
23600 Btu/hr Cooling |
Dimensions |
: |
33.3 in W x 70.5625 in H x 17.125 in D |
Filter Size |
: |
16 x 25 x 1 in |
Finish |
: |
Galvanized, Zinc-Coated |
Frequency Rating |
: |
60 Hz |
Fuse Rating |
: |
20 A |
HP Rating |
: |
1/5 hp Fan Motor, 1/6 hp Blower Motor |
HSPF Rating |
: |
6.6 |
Heating BTU Rating |
: |
23200 Btu/hr Heating |
Material |
: |
20 ga Steel |
Model |
: |
WH242-C |
Mounting Type |
: |
Wall |
Nominal Capacity |
: |
2 ton |
Phase |
: |
3 |
Refrigerant Type |
: |
R-22 |
Rotational Speed |
: |
1075 rev/min Fan Motor, 1100 rev/min Blower Motor |
SEER Rating |
: |
10.5 |
Series |
: |
WH |
Voltage Rating |
: |
460 VAC |
- Revision code (2)
- Commercial ventilator - motorized, (CRV-2 field installed part no)
- 2 in pleated filter
- Front (standard) supply air outlet
- Standard coil
- 3.9 A-rated load, 4 A branch circuit selection current, 25 A locked rotor compressor, 1.4 A fan motor, 1.1 A blower motor
- Self-contained energy efficient heating and cooling system
- Aluminum finned copper coils - grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency
- Twin blowers - move air quietly
- High pressure switch is built-in with a lockout circuit that resets from the room thermostat
- Full length mounting brackets
- Electrical components - are easily accessible for routine inspection and maintenance through a right side, service panel opening
- Electric heat strips - features an automatic limit and thermal cut-off safety control
- Suction accumulator - protects the reciprocating compressor from refrigerant flood back and prevents damage to the compressor bearing surfaces
- Condenser fan and motor shroud assembly slide out for easy access
- Slope top - standard feature for water run-off
- Top rain flashing - standard feature on all models
- Solid-state electronic heat pump control - provides efficient 30, 60 or 90 min defrost cycle
- 5 min compressor time delay - short cycle protection is standard, built-into the heat pump control
- Heat pump compressor